UV Electronic Ballasts

UV3000 Plus electronic UV ballast

BAL

UV Electronic Ballasts

UV electronic ballasts from 40 W to 3 kW with model-specific input, lamp current, control, IP rating and documented compliance details.

Selection Guide · Verified from supplied documents

UV Electronic Ballasts for Low-Pressure and Medium-Pressure UV Lamps

Choose a ballast by the exact lamp current, lamp count, starting method, input voltage, control method, enclosure rating and installation space. The model list below was compiled from the specification PDFs and product images supplied for this project.

40 W to 3 kWCompact lamp ballasts through medium-pressure digital UV power supplies
110-240 V and 380 VModel-dependent input options for export equipment projects
Single and multi-lampInstant-start, preheat and digitally controlled configurations
IP20 to IP65Protection rating varies by model and must be confirmed before ordering

Compliance and Documentation

Certificates and Standards Shown in the Supplied Specifications

CE

CE Marking

Explicitly marked “YES” for PL11-230-425-40 and PH21-230-800-150SR in the supplied sheets.

RoHS

RoHS

Explicitly marked “YES” for PL11-230-425-40 and PH21-230-800-150SR in the supplied sheets.

EN

EN 61347-1 / EN 61347-2-3

Listed under RFI/EMC or standards for multiple low-pressure ballast models.

IP

IP Protection Ratings

Documented ratings range from IP20 to IP65 depending on the exact enclosure and model.

Scope note: certification and IP claims apply only to the models whose supplied specification states them. A certificate copy and exact ordering code should be confirmed before quotation or regulatory submission.

Model Range

UV Ballast Models and Key Specifications

Model Input Power Lamp Output Starting / Control IP Documented Standards
EPS5-425-40 230 V 45 W input 1 lamp / 0.38-0.43 A Preheat, alarm indicators IP20 Not stated in supplied sheet
IPS60-MLT-800-95SK 110-240 V 102 W input 1 lamp / 800 mA Preheat, flow switch, alarm IP62 EN 61347-1 / EN 61347-2-3
PH2-230-800-150 230 V 165 W input 1 or 2 lamps / 800 mA Preheat, signal feedback IP62 EN 61347-1 / EN 61347-2-3
PH21-230-800-150SR 230 V 165 W input 1 lamp / 800 mA Preheat, signal feedback IP62 CE, RoHS, EN 61347-1 / EN 61347-2-3
PH8-MLT-2100-200 110-240 V 210 W input 1 or 2 lamps / 2100 mA Preheat, signal feedback See datasheet EN 61347-1 / EN 61347-2-3
PL1-230-800-100 230 V 40-106 W input 1 lamp / 800 mA Instant start, feedback See datasheet EN 61347-1 / EN 61347-2-3
PL11-230-425-40 230 V 21-55 W input 1 lamp / 425 mA Instant start, feedback See datasheet CE, RoHS, EN 61347-1 / EN 61347-2-3
PL18-800-2/155 120 / 230 V 345 W input 2 lamps / 0.75-0.85 A Instant start, LED status IP64 UL-certified internal wire; product certification not stated
PS80-230-2100-320L 230 V 365 W input 1 lamp / 2100 mA Preheat, 0-10 V dimming IP65 EN 61347-1 / EN 61347-2-3
PS9-230-AL-320P 230 V 365 W input 1 lamp / 1.8-2.1 A Preheat, PWM dimming IP20 EN 61347-1 / EN 61347-2-3
PS90-230-AL-2320 230 V 690 W input 1 lamp / 1.8-3.0 A Preheat, RS485 control IP20 EN 61347-1 / EN 61347-2-3
PS90-230-AL-800 230 V 850 W input 1 lamp / 3.5-7 A Preheat, RS485 control IP20 EN 61347-1 / EN 61347-2-3
MPLB-1PH-A-2000 230 V Up to 2100 W input 2000 W lamp / <9 A or 11 A PWM power control IP20 Not stated in supplied manual
HS-EPS1KW Single-phase 220 V 1 kW class 100-220 V output / max 10 A Vector control, RS485 IP52 Not stated in supplied manual
HS-EPS2KW Single-phase 220 V 2 kW class 160-220 V output / max 13 A Vector control, RS485 IP52 Not stated in supplied manual
HS-EPS3KW Three-phase 380 V 3 kW class 300-460 V output / max 12 A Vector control, RS485 IP52 Not stated in supplied manual

Values above are a sales-selection summary. Final matching must use the complete datasheet, lamp code and wiring requirements.

Fast Inquiry Matching

Send These Details for a Reliable Ballast Match

  1. Old ballast label or required ballast model.
  2. UV lamp model, lamp wattage, operating current and number of lamps.
  3. Input voltage and frequency at the installation site.
  4. Starting method, dimming, RS485, feedback and alarm requirements.
  5. Ballast dimensions, mounting holes, cable length, connectors and target IP rating.

Request Ballast Matching

Selection checklist

Information needed for a reliable match

Confirm before matching

Lamp wattage, operating current, tube configuration, input voltage and starting method.

Integration review

Connector, cable length, enclosure space, grounding, temperature and control interface.

Buyer deliverables

Recommended ballast platform, wiring reference, sample scope and quotation notes.

Samples and documentation

Final selection is confirmed against the buyer’s application and approved sample. Depending on the model and project, BIOSUN can prepare specifications, drawings, labels, packing details and available compliance records for review.

Inquiry Notes

For fast matching, send lamp model, tube length, diameter, wattage, base type, quantity and application. Photos of the old lamp label and installation system are helpful.

Technical review

Reviewed by the BIOSUN Application Engineering Team.

Published ranges and model information are checked against the product tables and supplied technical documents. Final selection still requires confirmation of the equipment, electrical platform, operating conditions and target-market requirements.

Reference review updated September 30, 2026