CE Marking
Explicitly marked “YES” for PL11-230-425-40 and PH21-230-800-150SR in the supplied sheets.
BAL
UV electronic ballasts from 40 W to 3 kW with model-specific input, lamp current, control, IP rating and documented compliance details.
Selection Guide · Verified from supplied documents
Choose a ballast by the exact lamp current, lamp count, starting method, input voltage, control method, enclosure rating and installation space. The model list below was compiled from the specification PDFs and product images supplied for this project.
Compliance and Documentation
Explicitly marked “YES” for PL11-230-425-40 and PH21-230-800-150SR in the supplied sheets.
Explicitly marked “YES” for PL11-230-425-40 and PH21-230-800-150SR in the supplied sheets.
Listed under RFI/EMC or standards for multiple low-pressure ballast models.
Documented ratings range from IP20 to IP65 depending on the exact enclosure and model.
Scope note: certification and IP claims apply only to the models whose supplied specification states them. A certificate copy and exact ordering code should be confirmed before quotation or regulatory submission.
Model Range
| Model | Input | Power | Lamp Output | Starting / Control | IP | Documented Standards |
|---|---|---|---|---|---|---|
| EPS5-425-40 | 230 V | 45 W input | 1 lamp / 0.38-0.43 A | Preheat, alarm indicators | IP20 | Not stated in supplied sheet |
| IPS60-MLT-800-95SK | 110-240 V | 102 W input | 1 lamp / 800 mA | Preheat, flow switch, alarm | IP62 | EN 61347-1 / EN 61347-2-3 |
| PH2-230-800-150 | 230 V | 165 W input | 1 or 2 lamps / 800 mA | Preheat, signal feedback | IP62 | EN 61347-1 / EN 61347-2-3 |
| PH21-230-800-150SR | 230 V | 165 W input | 1 lamp / 800 mA | Preheat, signal feedback | IP62 | CE, RoHS, EN 61347-1 / EN 61347-2-3 |
| PH8-MLT-2100-200 | 110-240 V | 210 W input | 1 or 2 lamps / 2100 mA | Preheat, signal feedback | See datasheet | EN 61347-1 / EN 61347-2-3 |
| PL1-230-800-100 | 230 V | 40-106 W input | 1 lamp / 800 mA | Instant start, feedback | See datasheet | EN 61347-1 / EN 61347-2-3 |
| PL11-230-425-40 | 230 V | 21-55 W input | 1 lamp / 425 mA | Instant start, feedback | See datasheet | CE, RoHS, EN 61347-1 / EN 61347-2-3 |
| PL18-800-2/155 | 120 / 230 V | 345 W input | 2 lamps / 0.75-0.85 A | Instant start, LED status | IP64 | UL-certified internal wire; product certification not stated |
| PS80-230-2100-320L | 230 V | 365 W input | 1 lamp / 2100 mA | Preheat, 0-10 V dimming | IP65 | EN 61347-1 / EN 61347-2-3 |
| PS9-230-AL-320P | 230 V | 365 W input | 1 lamp / 1.8-2.1 A | Preheat, PWM dimming | IP20 | EN 61347-1 / EN 61347-2-3 |
| PS90-230-AL-2320 | 230 V | 690 W input | 1 lamp / 1.8-3.0 A | Preheat, RS485 control | IP20 | EN 61347-1 / EN 61347-2-3 |
| PS90-230-AL-800 | 230 V | 850 W input | 1 lamp / 3.5-7 A | Preheat, RS485 control | IP20 | EN 61347-1 / EN 61347-2-3 |
| MPLB-1PH-A-2000 | 230 V | Up to 2100 W input | 2000 W lamp / <9 A or 11 A | PWM power control | IP20 | Not stated in supplied manual |
| HS-EPS1KW | Single-phase 220 V | 1 kW class | 100-220 V output / max 10 A | Vector control, RS485 | IP52 | Not stated in supplied manual |
| HS-EPS2KW | Single-phase 220 V | 2 kW class | 160-220 V output / max 13 A | Vector control, RS485 | IP52 | Not stated in supplied manual |
| HS-EPS3KW | Three-phase 380 V | 3 kW class | 300-460 V output / max 12 A | Vector control, RS485 | IP52 | Not stated in supplied manual |
Values above are a sales-selection summary. Final matching must use the complete datasheet, lamp code and wiring requirements.
Product Gallery
Compact 230 V ballast for 425 mA UV lamps.
Catalog image supplied; confirm the exact electrical sheet before quotation.
One- or two-lamp 800 mA preheat ballast.
800 mA ballast with CE and RoHS marked in the supplied specification.
Wide-input 2100 mA ballast for high-output UV lamps.
Catalog image supplied; electrical configuration to be confirmed.
High-power catalog model; confirm lamp current and control option.
Instant-start 800 mA ballast for one UV lamp.
Compact 425 mA ballast with CE and RoHS marked in the supplied sheet.
Two-lamp, 345 W input, IP64 instant-start ballast.
IP65 ballast with 0-10 V dimming for 2100 mA UV lamps.
RS485-controlled high-power ballast with adjustable lamp current.
Digital UV power supply product image; confirm project parameters before selection.
1 kW medium-pressure UV digital power supply.
2 kW medium-pressure UV digital power supply.
Fast Inquiry Matching
Selection checklist
Lamp wattage, operating current, tube configuration, input voltage and starting method.
Connector, cable length, enclosure space, grounding, temperature and control interface.
Recommended ballast platform, wiring reference, sample scope and quotation notes.
Final selection is confirmed against the buyer’s application and approved sample. Depending on the model and project, BIOSUN can prepare specifications, drawings, labels, packing details and available compliance records for review.
For fast matching, send lamp model, tube length, diameter, wattage, base type, quantity and application. Photos of the old lamp label and installation system are helpful.
Technical review
Published ranges and model information are checked against the product tables and supplied technical documents. Final selection still requires confirmation of the equipment, electrical platform, operating conditions and target-market requirements.
Reference review updated September 30, 2026