UVBIOSUN Contact us

PL SERIES · UV LAMP POWER

Instant-start UV Electronic Ballast

PL1-230-800-120

Instant Start UV electronic ballast with 800(720-880) mA lamp current.

Input power
40 W–120 W
Dimensions L×W×H
215 × 44 × 26 mm
Input
230V
Lamp current
800(720-880) mA
← Back to PL models

TECHNICAL DATA

Model specifications.

Input specifications

Input voltage
230V
Input voltage range
198V ~ 264V
Line frequency
50/60Hz
Maximum input current
0.58A@230V
Input power
40W-120W@230V
Power factor
≥0.90@100W
Inrush current
40A
Surge protection
Yes
Overcurrent protection
Yes

Lamp output & control

Compatible lamp references
GPHO357T5L/4P\GPH436T5L/HO\GPH846T5HO GPH893T5HO\GHO36T5L\TUV36T5HO\TUV55WHO TUV75WHO\TUV95WHOPL-L\GPH1148T5HO
Number of lamps
1
Lamp current
800(720-880) mA
Starting method
Instant Start
Signal feedback
5 VDC / 10 mA lamp-on feedback; lamp off: 0 VDC
Open-circuit protection
Yes
Constant-current operation
Yes
Listed standards
EN61347-1,EN61347-2-3

Operating conditions

Maximum case temperature (°C)
70
Minimum starting temperature (°C)
-10
Minimum operating temperature (°C)
-10
Maximum ambient temperature (°C)
45
Humidity / enclosure rating
5%-95%
Specified warranty conditions
2 Years@Tc,70°Cmax

Mechanical specifications

Weight
350g
Length including mount (mm)
215mm
Mounting-hole spacing (mm)
211mm
Width (mm)
44mm
Height (mm)
26mm
Input connection
WIRE UL1015 18AWG strandedblack/white 105℃ 600VAC 1*430mm
Output connection
WIRE UL1015 18AWG strandedred/yellow 105℃ 600VAC 1*650mm
Signal-feedback connection
WIRE UL1007 24AWG strandedred/black 80℃ 300VAC 1*650mm

INSTALLATION REFERENCE

Dimensions & connections.

Check the exact lamp, wiring and mounting arrangement with the approved order drawing.

BALLAST MATCHING

Let’s match the ballast
to your UV lamp.

Share the lamp code, operating current, supply voltage and installation space. Include a label photo when replacing an existing ballast.

Contact BIOSUN ↗

Review your message in WhatsApp before sending.