Nov 23, 2026 · Electronic Ballasts
Will a Replacement UV Light Ballast Fit the Existing Cabinet?
Check mounting-hole spacing, case dimensions, and cable clearance before ordering a replacement UV light ballast for an existing cabinet.
A replacement can match the lamp current and still miss the holes in the mounting plate. The PH2-230-800-150 has mounting points 190 mm apart. On the PH21-230-800-150SR they are 211 mm apart. Both are rated at 800 mA nominal. If the cabinet has two fixed holes 190 mm apart, the PH21 does not reuse that hole pattern as-is.
Measure From the Centers of the Mounting Points
Record the distance between the centers of the holes currently used on the cabinet plate. Photograph the plate with a ruler or mark the dimensions on its drawing. For a slotted mounting point, show the usable travel and the position the fastener can actually occupy. Compare those dimensions with the replacement drawing.
Check the ballast’s overall length separately. Atlantic Ultraviolet’s 10-1109 data sheet shows 18 in overall and a separate 16.75 in mounting dimension on the same drawing. Ask for both dimensions when a quotation gives only a single length. Atlantic Ultraviolet 10-1109 drawing, page 2

Check What Changes Between the Two Models
| Model | Overall case and mounts (L × W × H) | Mounting-point spacing | Cable connection |
|---|---|---|---|
| PH2-230-800-150 | 200 × 64 × 30 mm | 190 mm | Terminals |
| PH21-230-800-150SR | 215 × 44 × 30 mm | 211 mm | Fixed leads |
The PH21 is 20 mm narrower and 15 mm longer. Its mounting points are 21 mm farther apart. A buyer working from case width alone could select the narrower unit and still be unable to use the original mounting holes. Where the plate has slots, check whether both fasteners can line up at the same time. Keep the mounting change separate on the quote if the equipment team needs to review an adapter or a different plate.
Next, check how the cables will reach. A cabinet built around removable connections at the ballast may need a different harness arrangement when the replacement has fixed leads. Mark the terminal or lead exit, the nearest duct or obstruction, and where the harness joins. Use the available space with the cabinet closed to confirm the outline and cable route. Have the equipment team confirm the lamp load and electrical match separately.
Send One Marked-Up Photo With the Quote Request
Mark three things on the cabinet photo or drawing: mounting-point spacing, space available for the case, and where the cables must reach. Include the current ballast and lamp codes. Ask the supplier to confirm whether the proposed unit fits the existing plate and harness and to identify anything that would need to change.