PH SERIES · UV LAMP POWER

Preheat UV Electronic Ballast

PH8-MLT-2100-200

Preheat start UV electronic ballast with 2100 mA (1900–2300 mA) lamp current.

Input power
210 W
Dimensions L×W×H
250 × 65 × 38 mm
Input
110–240 V
Lamp current
2100 mA (1900–2300 mA)
← Back to PH models

TECHNICAL DATA

Model specifications.

Input specifications

Input voltage
110–240 V
Input voltage range
99–264 V
Line frequency
50/60 Hz
Maximum input current
1.93 A @ 110 V
Input power
210 W @ 110 V
Power factor
≥0.99 @ 210 W
Inrush current
40 A
Surge protection
Yes
Overcurrent protection
Yes

Lamp output & control

Compatible lamp references
1 × GPHHA834T6L / GPHHA100T6L / TUV130W XPT SE / TUV180W XPT SE; 2 × GPHA357T6
Number of lamps
1 or 2
Lamp current
2100 mA (1900–2300 mA)
Starting method
Preheat start
Signal feedback
5 VDC / 10 mA, or dry contact
Open-circuit protection
Yes
Constant-current operation
Yes
Listed standards
EN 61347-1 / EN 61347-2-3

Operating conditions

Maximum case temperature (°C)
80
Minimum starting temperature (°C)
−10
Minimum operating temperature (°C)
−10
Maximum ambient temperature (°C)
40
Humidity / enclosure rating
5%–95%
Specified warranty conditions
2 years at Tc ≤80°C

Mechanical specifications

Length including mount (mm)
250
Width (mm)
65
Height (mm)
38
Mounting-hole spacing (mm)
242
Input connection
14–18 AWG; strip 9–10 mm
Output connection
14–18 AWG; strip 9–10 mm
Signal-feedback connection
18–24 AWG; strip 9–10 mm
Potting
No

PDF body dimensions are used (250 × 65 × 38 mm); the sketch has different mounting dimensions. Confirm the approved drawing for installation.

BALLAST MATCHING

Let’s match the ballast
to your UV lamp.

Share the lamp code, operating current, supply voltage and installation space. Include a label photo when replacing an existing ballast.

Contact BIOSUN ↗