UVBIOSUN Contact us

PH SERIES · UV LAMP POWER

Preheat UV Electronic Ballast

PH2-230-800-150

Preheat Start UV electronic ballast with 800(720-880) mA lamp current.

Input power
165 W
Dimensions L×W×H
200 × 64 × 30 mm
Input
230V
Lamp current
800(720-880) mA
← Back to PH models

TECHNICAL DATA

Model specifications.

Input specifications

Input voltage
230V
Input voltage range
198V ~ 264V
Line frequency
50/60Hz
Maximum input current
0.72A@230V
Input power
165W@230V
Power factor
≥0.99@165W
Inrush current
40A
Surge protection
Yes
Overcurrent protection
Yes

Lamp output & control

Compatible lamp references
1*GPH1554T5HO, GHO64T5 ,TUV64T5HO,TUVPL-95WHO TL100W 2*GPH893T5HO,GPH846T5HO,GHO36T5,TUV75WHO TUV60WHO,TUV55WHO,TUV36T5HO
Number of lamps
1 or 2
Lamp current
800(720-880) mA
Starting method
Preheat Start
Signal feedback
5 VDC / 10 mA lamp-on feedback; lamp off: 0 VDC; dry-contact option
Open-circuit protection
Yes
Constant-current operation
Yes
Listed standards
EN61347-1,EN61347-2-3

Operating conditions

Maximum case temperature (°C)
70
Minimum starting temperature (°C)
-10
Minimum operating temperature (°C)
-10
Maximum ambient temperature (°C)
45
Humidity / enclosure rating
5%-85%/IP62
Specified warranty conditions
2 Years@Tc,70°Cmax

Mechanical specifications

Weight
TBD
Length including mount (mm)
200mm
Mounting-hole spacing (mm)
190mm
Width (mm)
64mm
Height (mm)
30mm
Input connection
16-18 AWG terminal wire; strip 8-10 mm
Output connection
16-18 AWG terminal wire; strip 8-10 mm
Signal-feedback connection
18-24 AWG terminal wire; strip 8-10 mm
Potting
Black potting compound

INSTALLATION REFERENCE

Dimensions & connections.

Check the exact lamp, wiring and mounting arrangement with the approved order drawing.

BALLAST MATCHING

Let’s match the ballast
to your UV lamp.

Share the lamp code, operating current, supply voltage and installation space. Include a label photo when replacing an existing ballast.

Contact BIOSUN ↗

Review your message in WhatsApp before sending.