UVBIOSUN Contact us

IPS SERIES · UV LAMP POWER

Preheat UV Electronic Ballast

IPS61-MLT-800-150S

Preheat Start UV electronic ballast with 800 mA lamp current.

Input power
165 W
Dimensions L×W×H
250 × 73 × 45 mm
Input
110V ~ 240V
Lamp current
800 mA
← Back to IPS models

TECHNICAL DATA

Model specifications.

Input specifications

Input voltage
110V ~ 240V
Input voltage range
99V ~ 264V
Line frequency
50/60Hz
Maximum input current
1.52A@110V
Input power
165W@110V
Power factor
≥0.99@165W
Inrush current
40A
Surge protection
Yes
Overcurrent protection
Yes

Lamp output & control

Compatible lamp references
1*GPH1554T5HO,GHO64T5,TUV64T5HO, TUVPL-95WHO,TL100W
Number of lamps
1
Lamp current
800 mA
Starting method
Preheat Start
Flow-switch control
Yes
Signal feedback
Audible and visual alarm
Open-circuit protection
Yes
Constant-current operation
Yes
Listed standards
EN61347-1,EN61347-2-3

Operating conditions

Maximum case temperature (°C)
70
Minimum starting temperature (°C)
-10
Minimum operating temperature (°C)
-10
Maximum ambient temperature (°C)
45
Humidity / enclosure rating
5%-85%/IP62
Specified warranty conditions
2 Years@Tc,70°Cmax

Mechanical specifications

Weight
TBD
Length including mount (mm)
250
Mounting-hole spacing (mm)
241
Width (mm)
73mm
Height (mm)
45mm
Input connection
Three-pin power cord (China standard)
Output connection
Sheathed cable, 4 cores × 0.5mm
Signal-feedback connection
ON
Potting
no

INSTALLATION REFERENCE

Dimensions & connections.

Check the exact lamp, wiring and mounting arrangement with the approved order drawing.

BALLAST MATCHING

Let’s match the ballast
to your UV lamp.

Share the lamp code, operating current, supply voltage and installation space. Include a label photo when replacing an existing ballast.

Contact BIOSUN ↗

Review your message in WhatsApp before sending.