Projects & partnerships

Application experience across odor control, appliances, transit and water treatment.

Selected references from BIOSUN company materials are organized here by application. Project conditions, treatment routes and supply scope vary; final product selection is confirmed against drawings, operating conditions and the required validation plan.

5,000–70,000 m³/h
Design-airflow examples in the supplied project record
4 application groups
Engineering projects, appliances, transit and water systems
Project-specific
Configuration, validation and documentation
Selected BIOSUN odor-control project site photographs
Selected project-site photographs from the supplied BIOSUN portfolio.

Project evidence

The portfolio is presented as usable engineering evidence.

Rather than publishing a dense customer table, the page groups representative work by problem, project scale and treatment route. Customer names are omitted where they are not needed to understand the application.

01

Application first

Start with the odor source, appliance, water system or transport environment.

02

Range, not false precision

Show the supplied design range and treatment route without claiming unverified removal results.

03

Engineering review

Confirm airflow, installation space, electrical platform, materials and target-market requirements.

04

Validation plan

Agree on samples, drawings, inspection points and performance verification before batch supply.

Selected applications

Representative projects from the supplied record.

Figures below describe documented project examples and are not universal product ratings.





Odor controlMunicipal facilities

Waste-transfer station odor treatment

Multiple municipal waste-transfer and waste-room projects in Guangdong were documented with site-specific enclosure and exhaust arrangements.

Example range
10,000–30,000 m³/h
Treatment route
Combined scrubber with photoplasma purification
Engineering scope

Review capture points, duct routing, corrosion exposure, available footprint, fan conditions and the required commissioning method.

Odor controlWastewater infrastructure

Wastewater pump-station odor control

A supplied Shenzhen pump-station reference records a higher-airflow biological treatment and photoplasma configuration.

Documented airflow
Approx. 51,000 m³/h
Treatment route
Biofilter with photoplasma purification
Engineering scope

Confirm source composition, humidity, pre-treatment, residence time, media maintenance and outlet verification points.

Odor controlIndustrial manufacturing

High-volume process exhaust purification

An electronics-manufacturing reference in the supplied record represents a high-volume photoplasma equipment application.

Documented airflow
Approx. 70,000 m³/h
Treatment route
Project-specific photoplasma purification
Engineering scope

Review contaminant profile, concentration, temperature, moisture, duct velocity, module loading and applicable workplace controls.

Rail transitStation support facilities

Transit-site waste and odor projects

Company materials list metro and rail references across major Chinese cities, including station and transfer-area odor-control applications.

Example range
10,000–15,000 m³/h
Project focus
Compact footprint, service access and site coordination
Engineering scope

Coordinate restricted installation windows, fire and electrical interfaces, access for maintenance and project-document requirements.

Appliance OEMCustomized modules

UV and photoplasma modules for home appliances

BIOSUN materials show cooperation references across air-conditioning and household-appliance brands for customized module development.

Supply platform
Typical DC 5–24 V development range
Customization
Housing, cable, connector, mounting and power
Engineering scope

Begin with the appliance drawing, airflow path, target treatment area, electrical interface, duty cycle and sample-approval plan.

Water treatmentComplete UV equipment

UV water systems from point-of-use to industrial flow

Stainless-steel and PVC product families support residential, commercial, aquaculture and industrial treatment projects.

Published product range
0.23–150 m³/h
System families
Compact stainless steel, PVC multi-lamp and industrial reactors
Engineering scope

Confirm water quality, UV transmittance, target dose, flow variation, pressure, connection, monitoring and cleaning requirements.

Selected cooperation references

Partner names grouped by industry instead of one crowded logo wall.

The names below are reproduced as text from the supplied BIOSUN company materials. The scope differs by project and product program.

Rail transit

Selected metro and rail references

Beijing SubwayGuangzhou MetroShenzhen MetroMTR CorporationTianjin MetroHarbin MetroNingbo Rail TransitChangsha MetroNanjing MetroChengdu MetroDalian MetroQingdao Metro

Discuss a transit application

Technical review

Reviewed for publication by the BIOSUN Application Engineering Team.

Project descriptions were normalized from supplied company materials. Airflow values describe selected design examples; removal efficiency, compliance and final configuration require project-specific test data and approval.

Publication review: September 30, 2026

Discuss your project

Have a similar odor, appliance, transit or water-treatment application?

Send the application, airflow or water-flow range, installation drawing, operating conditions and target market. BIOSUN will identify the appropriate engineering review path.

Send Project Details